NFPA 850: Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations
The NFPA 850 standard provides guidelines for fire protection in electric generating plants and high voltage direct current (HVDC) converter stations. This standard is crucial in ensuring the safety of personnel, equipment, and the surrounding community from the risks associated with fires in these facilities.
NFPA 850 is a book about Recommended Practices for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter (HVDC) Stations developed by the National Fire Protection Association (NFPA).
This handbook provides a framework for developing a Fire Protection Design Basis that considers various hazards to the specific facility such as fuels, lubricating oils, explosive dust, electrical equipment, and flammable liquids. The safety and continuity of systems and operations are all discussed in NFPA 850.
The National Fire Protection Association (NFPA) is an organization specialized in recommending best practices to prevent – or act against – fire. NFPA issues recommendations for all types of installations from buildings to substations.
In 2010, NFPA updated its Recommendations 850 “Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations” and included the Fast Depressurization System.
The NFPA Recommendations 850 defines 4 criteria for Fast Depressurization Systems:
- “Passive mechanical system”
- “Depressurizes the transformer a few milliseconds after the occurrence of an electrical fault”
- “Triggered by the dynamic pressure peak generated by the short circuit”
- “Activates within milliseconds before static pressure increases”
- The 2015 and 2020 editions have provided additional information, including a reference to an article from a group of experts analyzing an incident in which the FDS prevented an explosion.
Scope and Purpose
NFPA 850 applies to electric generating plants and HVDC converter stations, including those fueled by coal, gas, oil, and nuclear energy. The standard aims to provide a comprehensive framework for fire protection in these facilities, including requirements for fire detection, suppression, and prevention.
This recommended practice outlines fire safety recommendations for gas, oil, coal, and alternative fuel electric generating plants, including high voltage direct current converter stations and combustion turbine units used for electric generation.
NFPA 850 covers a number of important concerns. Here we have listed a few of them below:
- Fire and gas detection mapping.
- Fire protection for electric generating plants.
- Data center physical infrastructure installation and support.
- Continuous gas weight monitoring systems.
- Specifications and plans for fire protection systems.
- Electrical licensure information for burglar and fire systems And many more.
Key Requirements
1. Fire Hazard Analysis: A fire hazard analysis must be conducted to identify potential fire hazards and develop strategies for mitigating them.
2. Fire Detection and Alarm Systems: Fire detection and alarm systems must be installed and maintained to detect fires in their early stages and alert personnel.
3. Fire Suppression Systems: Fire suppression systems must be installed and maintained to extinguish fires quickly and effectively.
4. Fire Prevention Measures: Fire prevention measures must be implemented to prevent fires from occurring in the first place, including regular maintenance and inspection of equipment.
5. Training and Drills: Personnel must receive regular training and participate in drills to ensure they are prepared to respond to fires effectively.
Hazards Associated with Electric Generating Plants and HVDC Converter Stations
Electric generating plants and HVDC converter stations pose a range of hazards, including:
1. Electrical fires: Electrical fires can occur due to faulty wiring, equipment malfunctions, or other electrical hazards.
2. Fuel fires: Fuel fires can occur due to leaks or spills of fuel, such as coal, gas, or oil.
3. Chemical fires: Chemical fires can occur due to the presence of hazardous chemicals, such as hydrogen or chlorine.
4. Explosions: Explosions can occur due to the presence of flammable gases or vapors.
Benefits of Compliance
Compliance with NFPA 850 provides numerous benefits, including:
1. Enhanced safety: Compliance with NFPA 850 minimizes the risk of fires and explosions, ensuring the safety of personnel and the surrounding community.
2. Reduced risk of equipment damage: Compliance with NFPA 850 reduces the risk of equipment damage from fires and explosions, minimizing downtime and repair costs.
3. Regulatory compliance: Compliance with NFPA 850 helps ensure adherence to relevant regulations and standards.
4. Maintaining a space free of combustible continuity can stop fire spread. Flammable and combustible
liquids and gases should not be conveyed through the area.
5. This includes prohibiting oil piping.
6. Mechanical failure may result in the release of rotating parts or projectiles. Even a barrier might not
be effective in stopping the projectile.
Conclusion
NFPA 850 provides a comprehensive framework for fire protection in electric generating plants and HVDC converter stations. Compliance with this standard is essential in ensuring the safety of personnel, equipment, and the surrounding community from the risks associated with fires in these facilities.
However, the NFPA 850 Recommendation includes definitions that rely on implicit knowledge regarding a set of complicated and extremely rapid physical processes, including dielectric breakdown in transformer insulating oil, the generation of internal arcs, the vaporization of the oil, the build-up of pressures on the transformer tank, and the resultant dangerously high stresses on the tank wall.